ThisCalculator

Everyday

Studying Cell Migration in Confined Tissue

Updated · Standard formula, shown below

This guide walks you through the process of studying how cells migrate through confined tissue-like spaces in the lab. You will learn how to set up a 3D matrix or microfluidic device that mimics tissue constrictions, track cell movement, and analyze the data to understand migration modes. You’ll need basic cell culture experience and access to a fluorescence microscope.

What You’ll Need

  • Cell line (e.g., MDA-MB-231, HT1080) or primary cells
  • Culture medium appropriate for your cells (e.g., DMEM + 10% FBS)
  • Collagen I (rat tail) or Matrigel for 3D matrix
  • Microfluidic device with constriction channels (or custom-made PDMS mold)
  • Plasma cleaner or UV ozone for bonding PDMS to glass
  • Glass-bottom dishes or coverslips
  • Fluorescence microscope with time-lapse capability (inverted, with incubator)
  • Cell tracker dyes (e.g., CellTracker Green CMFDA) or fluorescent protein-expressing cells
  • Fibronectin or collagen coating solution
  • Syringes, tubing, and connectors for flow control
  • Image analysis software (ImageJ/Fiji, or commercial like Imaris)
  • Statistical analysis software (GraphPad Prism, R)

Step-by-Step

  1. Prepare the confinement device: If using a microfluidic device, bond the PDMS to a glass coverslip using a plasma cleaner (or UV ozone) according to the manufacturer’s protocol. Sterilize the assembled device by autoclaving or with 70% ethanol.
  2. Coat the channels: To mimic tissue-like adhesion, coat the channels with fibronectin (10 µg/mL in PBS) or collagen I (50 µg/mL) by injecting the solution and incubating at 37°C for 1 hour. Rinse with PBS.
  3. Prepare the 3D matrix: For a tissue-like environment, create a collagen I gel (2 mg/mL) by mixing collagen with 10X PBS, NaOH, and culture medium on ice to neutralize pH. Keep it on ice to prevent premature polymerization.
  4. Load the matrix (optional): If your device supports it, inject the cold collagen solution into the channels and incubate at 37°C for 30 minutes to polymerize. Alternatively, you can seed cells directly into the channels without a gel for a 2D-like confinement.
  5. Prepare cells: Label cells with a fluorescent tracker (e.g., 5 µM CellTracker Green in serum-free medium for 30 minutes) or use cells stably expressing a fluorescent protein. Ensure cells are in log-phase growth.
  6. Seed cells: Trypsinize cells, count them, and resuspend at a density of 1-2 × 10^6 cells/mL in culture medium. Inject 20-50 µL into the inlet of the device. Let cells attach for 1-2 hours in the incubator.
  7. Establish a chemotactic gradient (optional): To direct migration, fill the inlet with medium containing a chemoattractant (e.g., 10% FBS or EGF) and the outlet with serum-free medium. This creates a gradient.
  8. Set up time-lapse microscopy: Place the device on the microscope stage with an environmental chamber maintaining 37°C, 5% CO2, and humidity. Capture images every 5-10 minutes for 12-24 hours using a 10x or 20x objective. Use multiple stage positions to track many cells.
  9. Acquire images: Save images in TIFF format. Ensure the focus is stable; use autofocus if available.
  10. Track cell migration: Open the image sequence in ImageJ. Use the Manual Tracking plugin (or TrackMate) to follow individual cells over time. Record x,y coordinates for each frame.
  11. Analyze migration parameters: Calculate speed (total distance/time), displacement (net distance), and directionality (displacement/total path length). You can use the Chemotaxis and Migration Tool in ImageJ.
  12. Quantify confinement effects: For cells in constrictions, measure the time to pass through a constriction, the nuclear deformation (if you have a nuclear label), and the migration mode (mesenchymal vs amoeboid) based on cell shape.
  13. Repeat and statistically analyze: Perform at least three independent experiments. Use appropriate statistical tests (e.g., Student’s t-test, ANOVA) to compare conditions.

Common Mistakes

  • Air bubbles: Air bubbles in the channels can block flow and kill cells. Always degas media and use a syringe with a small needle to inject slowly.
  • Collagen gel polymerizing too early: If the gel sets before injection, it will clog the device. Keep all solutions on ice and work quickly.
  • Cell density too high: Overcrowding leads to contact inhibition and altered migration. Optimize seeding density.
  • Focus drift: Over long time-lapses, the focus can drift. Use a focus-maintenance system or check focus periodically.
  • Phototoxicity: Excessive light exposure can damage cells and alter migration. Use low light intensity and short exposure times.

Tips

  • Use a cell line known to migrate well in 3D, like MDA-MB-231 (breast cancer) or HT1080 (fibrosarcoma).
  • For better confinement, use channels narrower than the cell diameter (typically <10 µm).
  • Add a nuclear stain (e.g., Hoechst) to track nuclear deformation during passage.
  • Use a perfusion system to maintain stable gradients and remove waste.
  • Validate your matrix stiffness with rheology if possible, as stiffness affects migration.

Troubleshooting

  • Cells don’t enter the constriction channels: Increase the chemotactic gradient, or coat channels with a higher concentration of adhesion protein. Also, check that the channel width is not too small for your cell type.
  • Gel polymerizes in the syringe: Prepare smaller volumes and work faster. Keep the syringe on ice.
  • Cells die during imaging: Ensure CO2 and temperature are stable. Use a more robust culture medium (e.g., with HEPES buffer) and reduce light exposure.
  • Poor image quality: Use a high-NA objective, avoid overexposure, and clean the glass. If using a gel, reduce its thickness.
  • Migration speed is unexpectedly low: Check that the cells are viable and healthy. Verify that the matrix is not too stiff or too dense. Also, ensure the chemotactic gradient is present.

Frequently Asked Questions

What is the difference between 2D and 3D migration?

In 2D, cells migrate on a flat surface, which often leads to a spread, mesenchymal phenotype. In 3D, cells are surrounded by matrix and must squeeze through pores, leading to more physiologically relevant migration modes, including amoeboid movement.

How do I know if my cells are using amoeboid or mesenchymal migration?

Mesenchymal migration is characterized by elongated cell shape, strong adhesion, and degradation of the matrix. Amoeboid migration shows a rounded, blebbing shape with low adhesion and no matrix degradation. You can visualize these with phase-contrast or confocal imaging.

Can I use a transwell assay instead?

Transwell assays measure migration through a porous membrane, but they don’t provide real-time tracking or the same confinement geometry. Microfluidic devices are better for studying confined migration dynamics.

How long should I image for?

Imaging time depends on cell speed. For fast cells like neutrophils, 2-4 hours may suffice. For slower cells like fibroblasts, 12-24 hours is typical. Monitor the cells to ensure they remain healthy.

What if my cells don’t express fluorescent proteins?

You can use cell-permeable dyes like CellTracker, or transiently transfect with a fluorescent protein (e.g., GFP-Lifeact for actin). Always include a viability stain if using dyes.

How do I analyze nuclear deformation?

Use a nuclear dye (e.g., Hoechst) and measure the aspect ratio of the nucleus as it passes through a constriction. ImageJ can quantify this by fitting an ellipse to the nuclear signal.

Related

Method: the standard formula for this calculation, rounded as each result states. See how the calculators work or report an error.