Light Sheet Microscopy Sample Chambers: Model Guide

Updated · Standard formula, shown below

This article explains which sample chambers work with light sheet fluorescence microscopy (LSFM), organized by microscope model and application. You will learn the key chamber types, their mounting requirements, and how to match a chamber to your specific instrument and sample.

Background: Why the Chamber Matters in LSFM

Light sheet microscopy illuminates a sample from the side with a thin sheet of laser light, while detection occurs perpendicular to that sheet. This geometry imposes strict optical constraints on the sample chamber: the illumination path and the detection path must both pass through optically clear, flat or minimally distorting surfaces. Unlike epifluorescence or confocal setups, where the sample is often mounted on a standard glass slide, LSFM chambers must accommodate the orthogonal light paths and often require refractive index matching to avoid aberrations.

Chambers also serve a mechanical role: they hold the sample stable during long acquisitions, allow precise positioning in three axes, and often integrate with the microscope’s incubation or perfusion systems. Choosing the wrong chamber can lead to severe image degradation, sample drift, or even physical incompatibility with the stage.

How Light Sheet Chambers Work

The basic principle is that the chamber must be transparent to both the illumination and emission light paths. In most designs, the sample is suspended in a medium (often aqueous buffer) inside a cuvette or a custom-made holder. The illumination objective is placed on one side, and the detection objective on the adjacent side, at 90 degrees. The chamber walls must be flat and parallel to avoid refraction, or they must be made of a material with a refractive index matched to the immersion medium.

There are three main chamber geometries:

  • Cuvette-based: A rectangular glass or plastic cuvette with four clear sides. The sample is placed inside, often embedded in a gel or attached to a holder. This is common for zebrafish embryos, spheroids, and small organisms.
  • Immersion chambers: A larger bath filled with immersion medium (water, glycerol, or oil) where the objectives dip directly into the medium. The sample is mounted on a pedestal or a needle inside the bath. This is typical for cleared tissues and large samples.
  • Flow chambers: Designed for live-cell imaging with perfusion. They have inlet and outlet ports for media exchange, but must still maintain optical clarity.

Most commercial LSFM systems use a combination of these: a main chamber that holds the sample and a separate immersion medium for the objectives.

Model-Specific Chamber Compatibility

Here is a practical breakdown of compatible chambers for popular LSFM platforms. Note that ‘compatible’ means both physical fit and optical performance.

Zeiss Lightsheet Z.1

The Zeiss Lightsheet Z.1 uses a dedicated sample holder system. It accepts two types of chambers:

  • Standard cuvette: A 35 mm glass cuvette with a 10 mm path length. The sample is mounted on a metal or plastic holder that fits into the cuvette. This is for samples up to ~1 cm.
  • Large volume chamber: For cleared tissues, Zeiss offers a larger chamber that fits into the same holder but has a bigger opening. It uses a different mounting pin.

Third-party cuvettes with the same outer dimensions (12.5 mm x 12.5 mm x 45 mm) can be used, but they must be made of optical glass (e.g., UV-transparent) to avoid autofluorescence. The holder pin must match the Zeiss dovetail design.

LaVision BioTec Ultramicroscope (Miltenyi)

LaVision systems, now sold by Miltenyi Biotec, use an open immersion chamber. The sample is glued or pinned to a stage that moves in the Z-direction. The chamber is a large acrylic or glass tank filled with a clearing solution (e.g., ethyl cinnamate, dibenzyl ether). There is no cuvette; the objectives are dipped directly into the medium. Compatibility is determined by the sample stage and the working distance of the objectives. Any sample holder that fits the stage’s screw thread (usually M6) works.

Applied Scientific Instrumentation (ASI) LSFM

ASI offers a modular system with a variety of sample chambers. The most common is a stainless steel bath with a glass bottom and a removable insert. The insert holds a coverslip or a small dish. For multi-view imaging, they provide a rotating sample holder that accepts standard 35 mm Petri dishes or custom pins. The chamber is compatible with water or oil immersion objectives, but the user must ensure the working distance is sufficient.

Custom-built LSFM (OpenSPIM, mesoSPIM)

OpenSPIM and mesoSPIM are open-source designs. They typically use a simple glass cuvette (e.g., from Hellma or Starna) mounted on a 3D-printed holder. The cuvette is often a 10 mm or 20 mm path length. The key is to match the cuvette’s outer dimensions to the printed holder. For mesoSPIM, which is designed for cleared tissues, the chamber is a custom-machined acrylic tank with a glass coverslip window for illumination. The sample is placed in a separate glass cylinder filled with the clearing agent.

For any custom system, the chamber must have a flat optical window on the illumination side and a perpendicular flat window on the detection side. The thickness of the glass should be matched to the objective’s correction collar.

How to Choose a Chamber for Your Sample

Selecting the right chamber involves considering several factors:

  • Sample size and shape: For embryos and small spheroids (<1 mm), a cuvette with a gel mount is ideal. For larger cleared tissues (e.g., mouse brain), an open immersion bath is necessary.
  • Immersion medium: If you use a high-refractive-index clearing agent (e.g., RIMS, BABB), you need a chamber that is compatible with that solvent. Some plastics dissolve in organic solvents, so use glass or PTFE.
  • Objective working distance: The chamber walls must be within the working distance of both objectives. For high NA objectives with short working distances, you may need a chamber with a thin glass bottom (No. 1.5 coverslip).
  • Temperature control: For live samples, you need a chamber that can be heated or cooled. Many commercial chambers have built-in water jackets or Peltier elements.
  • Perfusion: If you need to add drugs or change media, a flow chamber with ports is required.

Common Problems and How to Avoid Them

Several recurring issues arise with LSFM chambers:

  • Refractive index mismatch: If the chamber wall has a different refractive index than the immersion medium, the light sheet will be distorted. Solution: use a chamber made of the same material as the immersion medium (e.g., glass for water, fused silica for glycerol) or match the refractive index of the medium to the glass.
  • Autofluorescence: Some plastics fluoresce under laser illumination, adding background noise. Use low-autofluorescence materials like quartz or specialized plastics (e.g., Zeonor).
  • Bubbles: Air bubbles in the immersion path scatter light. Degas the medium before use, and fill the chamber slowly.
  • Sample drift: If the sample is not firmly attached, it will drift during long acquisitions. Use a mechanical holder or a high-viscosity gel (e.g., low-melting agarose).
  • Cleaning: Chambers must be kept free of dust and fingerprints. Use lens paper and appropriate solvents; avoid scratching the optical windows.

Costs and Alternatives

Commercial chambers range from a few hundred to several thousand dollars. A simple glass cuvette costs $50-$200, while a full perfusion chamber with temperature control can exceed $2,000. For budget-conscious labs, alternatives include:

  • DIY chambers: Use a glass cuvette from a scientific supplier and 3D-print a holder. This is common in OpenSPIM setups.
  • Reusable Petri dishes: For inverted LSFM, a glass-bottom Petri dish can serve as a chamber if the illumination path is from the side.
  • Custom machined acrylic: For cleared tissue, you can machine a simple tank with a glass window.

Safety and Maintenance

When working with chambers, always wear gloves and safety glasses, especially when using organic solvents like BABB or ethyl cinnamate. These are toxic and flammable. Ensure proper ventilation. For live samples, maintain sterility. After each use, clean the chamber thoroughly with the appropriate solvent (e.g., ethanol for aqueous media, hexane for oil). Inspect the optical windows for scratches or coating damage. Store chambers in a dust-free container.

Frequently Asked Questions

Can I use a standard glass slide with light sheet microscopy?

No, a standard slide is not suitable because it only allows illumination from one side and does not provide a perpendicular path for the detection objective. You need a chamber that allows light to pass through at 90 degrees.

What is the best chamber for live zebrafish embryos?

For zebrafish embryos, a glass cuvette with a low-melting agarose mount is standard. The embryos are embedded in a drop of agarose inside the cuvette, and the cuvette is placed in the sample holder. This allows for multi-view imaging with minimal disturbance.

Can I use any glass cuvette for cleared tissue imaging?

No, cleared tissue often requires a high-refractive-index medium (e.g., 1.56), which may not be matched to standard glass (1.52). You need a chamber made of a material with a matching refractive index, such as specialized optical glass or a custom-machined chamber that allows the medium to surround the sample directly.

How do I know if a chamber will fit my microscope?

Check the manufacturer’s specifications for the sample holder dimensions and the stage mounting mechanism. For custom systems, measure the physical space and the objective working distances. Many suppliers provide CAD files for their chambers.

Do I need a special chamber for multi-view imaging?

Multi-view imaging requires rotating the sample relative to the light sheet. Some chambers have a built-in rotation mechanism (e.g., a rotating sample holder). Alternatively, you can use a chamber that allows the sample to be rotated manually between acquisitions, but this is less precise.

Can I use a chamber made of plastic for live-cell imaging?

Yes, but only if the plastic is low-autofluorescence and compatible with your medium. Many live-cell chambers are made of a cyclic olefin copolymer (COC) that has good optical clarity and low autofluorescence. However, always test for background signal before starting a long experiment.